IIR document
ENERGY SAVING AND IMPROVEMENT IN THE MAINTENANCE OF GAS-FIRED ABSORPTION WATER CHILLER/HEATER USING MICROPROCESSOR BASED CONTROLLER.
Author(s) : IKARI M., KUROSAWA S., IWAMA E.
Summary
THE AUTHORS REPORT A NEW CONTROLLING SYSTEM WHICH OPERATES 2 TO 4 UNITS. THE MAJOR FUNCTIONS ARE: (1) CONTROL OF SCHEDULED OPERATION ; (2) CONTROL OF NUMBER OF RUNNING UNITS ; (3) CONTROL OF OUTGOING WATER TEMPERATURE ; (4) CONTROL OF WATER VOLUME ; AND (5) CONTROL OF DILUTING OPERATION TIME. FUNCTIONS 2, 3 AND 4 CONTRIBUTE GREATLY TO ENERGY CONSUMPTION. THROUGH FUNCTION 2, THE EFFICIENCY OF THE HEAT SOURCE MACHINE AT LOW LOAD IS IMPROVED. FUNCTION 3 VARIES THE OUTGOING WATER TEMPERATURE ACCORDING TO EXTERNAL TEMPERATURE AND LOAD SIZE. IN FUNCTION 4, THE PUMP OPERATION IS CONTROLLED BY AN INVERTER. IT WAS SHOWN THAT THE CONTROLLER SYSTEM CUTS DOWN THE GAS CONSUMPTION BY 14% AND HEELTIOR4RUM THEREFORE THE INITIAL INVESTMENT CAN BE RECOVERED IN ABOUT 2,5 YEARS.
Available documents
Format PDF
Pages: 540-546
This document is to be digitised and will be available within 10 working days
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: ENERGY SAVING AND IMPROVEMENT IN THE MAINTENANCE OF GAS-FIRED ABSORPTION WATER CHILLER/HEATER USING MICROPROCESSOR BASED CONTROLLER.
- Record ID : 1988-1239
- Languages: English
- Source: Development in refrigeration, refrigeration for development. Proceedings of the XVIIth international Congress of Refrigeration.
- Publication date: 1987/08/24
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (509)
See the conference proceedings
Indexing
-
BETTER CONTROL THROUGH COMPUTERS.
- Author(s) : WILLIAMS V. A.
- Date : 1982
- Languages : English
View record
-
DEVELOPMENT OF INTELLIGENT GAS-FIRED ABSORPTION...
- Author(s) : KUROSAWA S., NAKAMURA S.
- Date : 1987
- Languages : English
View record
-
Case for hybrid gas/electric chiller plants: op...
- Author(s) : MECKLER M.
- Date : 1997
- Languages : English
- Source: J. Energy Eng. - vol. 94 - n. 5
View record
-
THE CHOICE BETWEEN CENTRAL OR INDIVIDUAL REFRIG...
- Author(s) : MATSUOKA S., KITAGAWA T., NAGATO N.
- Date : 1987
- Languages : Japanese
- Source: Refrigeration - vol. 62 - n. 716
View record
-
PARALLEL FLOW CHILLER-HEATER.
- Author(s) : FALLEK M.
- Date : 1985
- Languages : English
View record