IIR document
Experimental drop-in replacement of R404A for warm countries using the low GWP mixtures R454C and R455A.
Author(s) : MOTA BABILONI A., HARO ORTUNO J., NAVARRO-ESBRÍ J., et al.
Type of article: Article, IJR article
Summary
This article presents an analysis of the feasibility of R454C and R455A, two new low global warming potential (GWP of 148) refrigerants, in vapor compression refrigeration systems as alternatives to R404A for warm countries. R454C and R455A can be the most viable low GWP options to perform a direct replacement of R404A because of the similar characteristics. They only present meaningful differences in flammability, critical temperature, temperature glide and vapor density. The analysis is based on an experimental comparison of R404A with R454C and R455A, using a fully instrumented experimental setup equipped with Internal Heat Exchanger (IHX) at condensation temperatures that represent operating conditions of warm countries. The experimental results show that cooling capacity of the replacements is slightly lower than R404A, being the Coefficient of Performance (COP) of the new mixtures 10–15% higher than that of R404A, especially at higher condensation temperatures. The results also show that the adoption of an IHX is not recommended with the alternatives due to the discharge temperature increase and the low energy performance benefit.
Available documents
Format PDF
Pages: 136-145
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Experimental drop-in replacement of R404A for warm countries using the low GWP mixtures R454C and R455A.
- Record ID : 30023996
- Languages: English
- Subject: HFCs alternatives
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 91
- Publication date: 2018/07
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2018.05.018
Links
See other articles in this issue (25)
See the source
Indexing
-
Themes:
HFCs;
Blends - Keywords: R454C; Drop-in; R455A; R404A; Performance; Mixture; HFO; HFC; Expérimentation; Hot climate
-
Test of condensing units performance and operat...
- Author(s) : HADDAD E., MONTEL V., ROBERTS N., ZOUGHAIB A., SAAB S.
- Date : 2021/06
- Languages : English
- Source: 2nd IIR Conference on HFO Refrigerants and Low GWP Blends
- Formats : PDF
View record
-
Examining low global warming potential hydroflu...
- Author(s) : SPLETZER S., MEDINA J., HUGHES J.
- Date : 2019/08/24
- Languages : English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
View record
-
Experimental investigation on the low-GWP HFC/H...
- Author(s) : ORUÇ V., DEVECIOGLU A. G.
- Date : 2021/08
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 128
- Formats : PDF
View record
-
Evaporation heat transfer of the low GWP altern...
- Author(s) : KIM C. H., KIM N. H.
- Date : 2021/08
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 128
- Formats : PDF
View record
-
Condensation heat transfer and pressure drop of...
- Author(s) : LEE B. M., GOOK H. H., LEE Y. W., PARK D. H., KIM N. H.
- Date : 2021/08
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 128
- Formats : PDF
View record