IIR document
Experimental performance of an R-22-based refrigeration system for use with R-1270, R-438A, R-404A and R-134a.
Author(s) : PANATO V. H., PORTO M. P., BANDARRA FILHO E. P.
Type of article: Article, IJR article
Summary
In this work, the alternative refrigerants were evaluated as a drop-in of an R-22-based refrigeration system. The tested system comprises a variable-speed scroll compressor, an electronic expansion valve, a hot-and-cold water circuit and their respective heat exchangers. To make a fair comparison among fluids, only the lubricant type and refrigerant charge were varied to ensure good system functionality. The system performance was evaluated, varying the expansion valve opening to achieve evaporation temperatures of -5?°C, -10?°C and -15?°C. The same methodology was applied for various frequencies using an inverter drive. It was carried out in more than 200 experiments, and the response surface method was used to analyze the results. For all tested conditions, the R-438A was the most flexible alternative among the tested refrigerants as a drop-in of R-22 operating with a scroll compressor since the system operated in a wider range of values. Meanwhile, the R-1270 had the highest cooling capacity value and the lowest TEWI.
Available documents
Format PDF
Pages: 108-117
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Experimental performance of an R-22-based refrigeration system for use with R-1270, R-438A, R-404A and R-134a.
- Record ID : 30022491
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 83
- Publication date: 2017/11
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2017.07.010
Links
See other articles in this issue (13)
See the source
Indexing
-
Themes:
HCFCs;
Hydrocarbons - Keywords: TEWI; R438a; R134a; R1270; Comparison; Low GWP; R404A; R22; Substitute; Performance
-
Considerazioni sui refrigeranti con basso GWP n...
- Author(s) : BELLA B., KAEMMER N.
- Date : 2011
- Languages : Italian
- Source: Industria & Formazione - vol. 35 - n. 354
View record
-
Energy comparison based on experimental results...
- Author(s) : CABELLO R., ANDREU-NACHER A., SÁNCHEZ D., LLOPIS R., VIDAN-FALOMIR F.
- Date : 2023/04
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 148
- Formats : PDF
View record
-
Overview of low GWP mixtures for the replacemen...
- Author(s) : HEREDIA-ARICAPA Y., BELMAN-FLORES J. M., MOTA BABILONI A., SERRANO-ARELLANO J., GARCIA PABON J. J.
- Date : 2020/03
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 111
- Formats : PDF
View record
-
Theoretical comparison of low GWP alternatives ...
- Author(s) : MOTA BABILONI A., NAVARRO-ESBRÍ J., BARRAGAN A., et al.
- Date : 2014/08
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 44
- Formats : PDF
View record
-
Energy performance evaluation of R1234yf, R1234...
- Author(s) : SÁNCHEZ D., CABELLO R., LLOPIS R., et al.
- Date : 2017/02
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 74
- Formats : PDF
View record