Summary
The frosting process on the surface of the fin-and-tube evaporator and the dynamic performance of an air source heat pump (ASHP) adopting R-410A refrigerant were investigated experimentally. The frost thickness was measured by using micro-photography, and the frost accumulation mass was estimated in terms of the difference in measured humidity before and after the test evaporator. The experimental results indicate that the frost layer thickness increases in a manner of the stepwise pattern as quickly increasing, slowly increasing (or not increasing) and rapidly increasing during the frost formation process. Corresponding to the rapid increasing of the frost thickness, the performance of the ASHP unit deteriorates in the third stage. It is suggested that the vicious spiral formed by the interaction between the frost growth and the drops in the wall temperature and the air flow rate mainly causes the rapid performance deterioration in the third stage. In the meantime, it is found that the performance of the ASHP system, the frost growth rate and the duration of the frost-growth cycle are strongly affected by outdoor air relative humidity under frosting conditions.
Available documents
Format PDF
Pages: ICR07-E2-694
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Experimental study of interaction between frost growth on evaporator and dynamic characteristics of an air source heat pump.
- Record ID : 2008-0668
- Languages: English
- Source: ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Publication date: 2007/08/21
Links
See other articles from the proceedings (839)
See the conference proceedings
-
Effects of airflow maldistribution on the perfo...
- Author(s) : GONG J. Y., YUAN X. L., HU W. X., et al.
- Date : 2007/08/21
- Languages : English
- Source: ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
View record
-
Performance of a heat pump type air conditioner...
- Author(s) : LIU Y., WANG F., WANG T., et al.
- Date : 2008/04/05
- Languages : English
- Source: Cryogenics and refrigeration. Proceedings of ICCR'2008.
View record
-
Simulation of evaporator for indirect cooling r...
- Author(s) : LIAO Y., DING G., LIN E., et al.
- Date : 2007/12
- Languages : Chinese
- Source: Journal of Refrigeration - vol. 28 - n. 118
- Formats : PDF
View record
-
Self healing, slippery surfaces for HVAC&R syst...
- Author(s) : YU R., JACOBI A. M.
- Date : 2014/07/14
- Languages : English
- Source: 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Experimental analytical investigation on surfac...
- Author(s) : HU D., GUO B., XU C., et al.
- Date : 2007/08/21
- Languages : English
- Source: ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
View record