Field Monitoring of a variable-speed integrated heat pump/water heating appliance.
Author(s) : FANNEY A. H.
Type of monograph: Report
Summary
This report summarizes a study in which a variable-speed integrated heat pump/water heating appliance was monitored for 2 years while meeting the space conditioning and water heating needs of an occupied residence. Experimental results are presented which show that the total energy consumed by the residence was significantly reduced compared to previous years in which a wood stove, and window air-conditioners were used.
Details
- Original title: Field Monitoring of a variable-speed integrated heat pump/water heating appliance.
- Record ID : 1994-0696
- Languages: English
- Publication: NIST (National Institute of Standards and Technology) - United states/United states
- Publication date: 1993
- Collection:
- Source: Source: n. 171; 53 p. (21.6 x 28); fig.; tabl.
- Document available for consultation in the library of the IIR headquarters only.
Indexing
-
Hôtels - restaurants. Bâtiments à hautes perfor...
- Author(s) : Ademe, AICVF
- Date : 1992
- Languages : French
View record
-
Wärmerückgewinnung durch Wärmepumpen.
- Author(s) : IZW, DKV
- Date : 2001/12
- Languages : German
View record
-
Speciale editie: koude uit warmte.
- Date : 2011
- Languages : Dutch
View record
-
Heat pumps in Norway.
- Author(s) : Res. Counc. Nor.
- Date : 1993/04
- Languages : English
View record
-
Advanced energy design guide for small office b...
- Author(s) : ASHRAE
- Date : 2004
- Languages : English
View record