HEAT AND MASS TRANSFER UNDER DYNAMIC CONDITIONS OF A COMPOSITE INSULATED WALL. FIELD EXPERIMENTS UNDER ACTUAL CLIMATIC CONDITIONS.

TRANSFERT DE CHALEUR ET DE MASSE EN REGIME DYNAMIQUE DANS UNE PAROI COMPOSITE ISOLANTE. EXPERIMENTATION VRAIE GRANDEUR EN SITUATION CLIMATIQUE REELLE.

Author(s) : DEMARS Y., LANGLAIS C.

Type of article: Periodical article

Summary

VAPOUR TRANSFER BY DIFFUSION CAN BE NEGLECTED AGAINST OTHER FORMS OF MOISTURE TRANSFER. AFTER STATIONARY TESTS INTHE LABORATORY, THE AUTHORS ANALYSED THE CONSEQUENCES OF VAPOUR TRANSFER THROUGH A CONCRETE WALL WITH INSULATION ON THE INNER FACE AND EXPOSED TO SEVERE ACTUAL CLIMATIC CONDITIONS. NO DRIPPING OF WATER ON THE SUSTAINING WALL WAS OBSERVEDNOR ANY CONDENSATION ON THE INSULATION. (Bull. CNRS, FR., 83-730-15917.

Details

  • Original title: TRANSFERT DE CHALEUR ET DE MASSE EN REGIME DYNAMIQUE DANS UNE PAROI COMPOSITE ISOLANTE. EXPERIMENTATION VRAIE GRANDEUR EN SITUATION CLIMATIQUE REELLE.
  • Record ID : 1984-0897
  • Languages: French
  • Source: DGRST - 79.7.1507; 100 p.; 14 ref.
  • Publication date: 1982

Links


See the source