Influence factors in performance of the two-stage compression transcritical R744 cycle.
Number: pap. ID: 250
Author(s) : ALMEIDA I. M. G., BARBOSA C. R. F.
Summary
This study is a theoretical analysis of a two-stage transcritical cooling cycle using R744 (carbon dioxide) as a refrigerant. The effect of the intercooling process on performance in the two-stage transcritical system is subjected to varying pressures in a gas cooler. Performance comparison between the single stage and two-stage cycle is also subject to the same operating conditions. The authors assessed the effects on system performance of pressure in the gas cooler, isentropic compressor efficiency, amount of intercooling between the two compression stages and discharge temperature of the refrigerant from the gas cooler. Thermodynamic analysis was carried out with CoolPack software, considering an evaporation temperature of -10°C and refrigeration capacity of 5 kW. Results show the coefficient of performance (COP) for the two-stage cycle is superior to the single stage cycle. Two-stage compression was found to reduce energy consumption. On the whole, two-stage compression and the intercooling process are significant in increasing COP for these systems.
Available documents
Format PDF
Pages: 9 p.
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Influence factors in performance of the two-stage compression transcritical R744 cycle.
- Record ID : 30002326
- Languages: English
- Source: Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Publication date: 2011/08/21
Links
See other articles from the proceedings (569)
See the conference proceedings
Indexing
-
Comparison and analysis of CO2 transcritical cy...
- Author(s) : FU L., LI Q., XU R.
- Date : 2007/09
- Languages : Chinese
- Source: Refrigeration - vol. 26 - n. 3
View record
-
A comparative study of the carbon dioxide trans...
- Author(s) : CHEN Y., LUNDQVIST P., JOHANSSON A., et al.
- Date : 2006/12
- Languages : English
- Source: Applied Thermal Engineering - vol. 26 - n. 17-18
View record
-
Estudio de un ciclo de CO2 de compresón de dobl...
- Author(s) : SHIN E., KWAK M., KIM S., et al.
- Date : 2011/07
- Languages : Spanish
- Source: Frío Calor Aire acondicionado - vol. 39 - n. 438
- Formats : PDF
View record
-
The study of a two-stage compression CO2 cycle ...
- Author(s) : SHIN E., KWAK M., KIM S., et al.
- Date : 2010/04/12
- Languages : English
- Formats : PDF
View record
-
EXERGETIC ANALYSIS OF MULTISTAGE VAPOUR COMPRES...
- Author(s) : FORNASIERI E.
- Date : 1984
- Languages : Italian
- Source: Industria italiana del Freddo - vol. 38 - n. 4
View record