Performance analysis of a refrigerating system with a grooved-tube evaporator.

Author(s) : CELIK S., NSOFOR E. C.

Type of article: Article

Summary

A grooved-tube heat exchanger was developed and applied as an evaporator of a refrigerating system. Studies were carried out to evaluate the performance of the refrigerator. Isobutane (R-600a) was employed as the working fluid. Same studies were performed on the system but with the same size of a regular-tube evaporator. The two refrigerating systems were compared in terms of heat exchanger effectiveness, coefficient of performance (COP), and two-phase pressure drop. The heat exchanger effectiveness of the grooved-tube evaporator was found to be higher compared to the regular-tube evaporator. COP of the system with the grooved-tube evaporator was also observed to be higher. Although the pressure drop for the grooved-tube evaporator was slightly higher than that for the regular tube evaporator, the compressor demand for this increase was not very significant.

Details

  • Original title: Performance analysis of a refrigerating system with a grooved-tube evaporator.
  • Record ID : 30014845
  • Languages: English
  • Source: Applied Thermal Engineering - vol. 73 - n. 1
  • Publication date: 2014/12
  • DOI: http://dx.doi.org/10.1016/j.applthermaleng.2014.08.033

Links


See other articles in this issue (44)
See the source