PERFORMANCE TEST OF R12 ALTERNATES IN A HERMETIC COMPRESSOR.

Author(s) : ZHENG J., PELAVA J. W.

Summary

THE PAPER PRESENTS MEASUREMENT DATA ON THE CALORIMETER TESTS OF A HERMETIC COMPRESSOR. RESULTS FROM COMPRESSOR CALORIMETER TESTS ON THE R12/MINERAL OIL REPLACEMENT CANDIDATES, INCLUDING R134A/PAG OIL AND MIXTURES OF R22-R124/ALKYLBENZENE OIL, ARE DISCUSSED. RESULTS SHOW THAT BOTH R134A AND THE R22-R124 BLEND CAN ACHIEVE COMPARABLE PERFORMANCES UNDER MOST CONDITIONS WITH MINIMAL TRADE-OFF.

Available documents

Format PDF

Pages: 871-875

This document is to be digitised and will be available within 10 working days

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: PERFORMANCE TEST OF R12 ALTERNATES IN A HERMETIC COMPRESSOR.
  • Record ID : 1992-2085
  • Languages: English
  • Source: New challenges in refrigeration. Proceedings of the XVIIIth International Congress of Refrigeration, August 10-17, 1991, Montreal, Quebec, Canada.
  • Publication date: 1991/08/10