Practical interim solutions for existing R12 and R502 installations: technical data and case studies on R409A and R408A.
Author(s) : BRUBAKER M., ROLOTTI G., RADICE P.
Summary
The paper summarizes the data on two interim HCFC blends, Forane R409A and R408A, to be used on retrofit applications of R12 and R502 equipment. The main advantage of these blends, in addition to their similar operating conditions to the refrigerant they replace, is the fact that they are compatible with any oil, even mineral oil, on most applications making for simplified retrofit procedures. Information on the miscibility of R409A and R408A with mineral oil is presented. Data is presented detailing flammability information generated in accordance to Underwriters Laboratories and ASHRAE conditions. Several case studies are presented showing actual equipment data based on retrofits, comparing conditions before and after the procedure to demonstrate how suitable the blends are for retrofitting.
Details
- Original title: Practical interim solutions for existing R12 and R502 installations: technical data and case studies on R409A and R408A.
- Record ID : 1996-3263
- Languages: English
- Source: Stratospheric Ozone Protection for the 90's. 1995 International CFC and Halon Alternatives Conference & Exhibition. Conference proceedings.
- Publication date: 1995/10/23
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (58)
See the conference proceedings
Indexing
-
Themes:
CFCs;
Blends - Keywords: R409a; R502; R408a; R12; Substitute; Mixture; Refrigerating plant; Flammability; Retrofitting; Refrigerant
-
Energy efficient interim solutions for existing...
- Author(s) : RICKETTS M., BRUBAKER M.
- Date : 1996/10/21
- Languages : English
- Source: International Conference on Ozone Protection Technologies. Conference proceedings.
View record
-
Retrofitting refrigerating plants in the Mercad...
- Date : 1996/09
- Languages : Spanish
- Source: Refrig. Frial - n. 40
View record
-
Replacement of CFC-12 and R502 for commercial a...
- Author(s) : BARREAU M., WEISS P., RUIZ E.
- Date : 1998/03
- Languages : English
- Source: Celsius - vol. 26 - n. 3
View record
-
CFC alternatives for refrigeration: more than 2...
- Author(s) : WEISS P., BARREAU M., ROLOTTI G.
- Date : 1994/10
- Languages : English
- Source: Elf Atochem - 10 p.; 6 tabl.; 5 ref.
View record
-
Long-term solutions for CFC replacement in refr...
- Author(s) : BARREAU M.
- Date : 1998/03/04
- Languages : English
- Source: Cooling trends in an African context. The Frigair '98 International Refrigeration and Air Conditioning Conference.
View record