Refrigerant maldistribution in brazed plate heat exchanger evaporators. Part A: Testing campaign and experimental results.
Author(s) : NAVARRO-PERIS E., ALVAREZ-PINEIRO L., ALBALADEJO P., SCHNABEL L., CORBERÁN J. M.
Type of article: IJR article
Summary
The refrigerant distribution in a brazed plate heat exchanger evaporator with distributor has been studied with a thermographic camera working under different conditions of inlet vapor quality, superheat, and water temperature drop. The thermographies have shown a clear uneven thermal distribution except when superheat is null. In most of the cases, they show that a great part of the liquid accumulates at the end channels of the evaporator. The degradation of the evaporator performance is higher when the water temperature drop has a similar or higher value than the superheat. On the other hand, when the superheat is significantly higher than the water temperature drop, the evaporator performance is very similar to situations in which there is an even distribution of the refrigerant. The registered evaporation temperatures are much lower for the case of 13 K of water temperature drop, highlighting the importance of the influence of this parameter on the evaporator performance. This research is described in two parts, Part A (present paper) including the description of the experimental campaign, the obtained experimental results and the results discussion and Part B including an analysis of the degradation of the evaporation temperature due to the refrigerant maldistribution as well as a deeper analysis of the registered temperatures and of the causes for the great degradation observed when the water temperature drop is increased.
Available documents
Format PDF
Pages: 119-128
Available
Free
Details
- Original title: Refrigerant maldistribution in brazed plate heat exchanger evaporators. Part A: Testing campaign and experimental results.
- Record ID : 30029120
- Languages: English
- Subject: Technology
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 131
- Publication date: 2021/11
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2021.04.002
- Document available for consultation in the library of the IIR headquarters only.
Links
- See translations: Refrigerant maldistribution in brazed plate heat exchanger evaporators. Part B: Analysis of the influence of maldistribution on the evaporator performance.
See other articles in this issue (95)
See the source
-
Analysis of the refrigerant maldistribution of ...
- Author(s) : ALVAREZ L., ALBALADEJO P., NAVARRO-PERIS E., SCHNABEL L., CORBERÁN J. M.
- Date : 2021/08/31
- Languages : English
- Source: 13th IEA Heat Pump Conference 2021: Heat Pumps – Mission for the Green World. Conference proceedings [full papers]
- Formats : PDF
View record
-
Investigation on performance and refrigerant di...
- Author(s) : WEI W., XU G., JI J.
- Date : 2024/03
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 159
- Formats : PDF
View record
-
An infrared thermography based quantification m...
- Author(s) : LI W., HRNJAK P.
- Date : 2021/05
- Languages : English
- Source: 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Two-phase refrigerant flow in the inlet header ...
- Author(s) : LI W., HRNJAK P.
- Date : 2021/05
- Languages : English
- Source: 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
A new method for estimating the refrigerant dis...
- Author(s) : ZHANG S., LI Y., XU Y., YANG J., WANG Q.
- Date : 2021/06
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 126
- Formats : PDF
View record