Refrigerated hydrogen gas jet for the Fermilab antiproton accumulator.

Summary

The jet delivers a defined stream of hydrogen gas which travels through a series of vacuum chambers and then intersects the circulating antiproton beam. The goal of the upgrade is to provide a hydrogen gas stream at least twice as dense as used for the earlier experiment. This is achieved by cooling the stream to below 30 K using a Gifford-McMahon refrigerator.

Details

  • Original title: Refrigerated hydrogen gas jet for the Fermilab antiproton accumulator.
  • Record ID : 1997-2621
  • Languages: English
  • Source: Advances in cryogenic engineering.
  • Publication date: 1996/07/17
  • Document available for consultation in the library of the IIR headquarters only.