IIR document

Research on temperature distribution in vertical direction of refrigerated display cabinets and improvement of back panel flow.

Author(s) : LU Y. L., XUE M. D., YUAN P., et al.

Summary

Experimental and computational methods are used to investigate temperature distribution in vertical direction of open vertical refrigerated display cabinets. Results show that the temperature difference is very large, the maximum temperature difference was over 9.0°C, the least was approximately 1.5°C, moreover, the difference of top and bottom floor was about 7.5°C, and the difference of the 2nd and 3rd floor was 5.2°C. The main reason is that gradual temperature increase of air curtain and the irrational distribution of back panel flow. Then 4 and 3 rows of pores formed back panel flow are added in bottom and the 2nd floor, respectively. The results are validated by experimental tests performed in accordance with the EN441 Standard.

Available documents

Format PDF

Pages: ICR07-B2-98

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Research on temperature distribution in vertical direction of refrigerated display cabinets and improvement of back panel flow.
  • Record ID : 2008-0237
  • Languages: English
  • Source: ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
  • Publication date: 2007/08/21

Links


See other articles from the proceedings (839)