TECHNOLOGICAL EQUIPMENT FOR PRELIMINARY MILK TREATMENT ON FARMS USING ARTIFICIAL COLD.

[In Russian. / En russe.]

Author(s) : KRASNOV V. S.

Type of article: Article

Summary

EQUIPMENT FOR TREATMENT OF MILK ON FARMS WITH 100, 200 OR 400 DAIRY COWS USING DIFFERENT MILKING METHODS IS DESCRIBED AS WELL AS EQUIPMENT FOR CENTRALIZED MILK TREATMENT (CAPACITY 6 OR 12 T). UTILIZATION OF HEAT FROM MILK COOLING FOR WATER HEATING REDUCED TOTAL HEAT CONSUMPTION 3-4 FOLDS ; EVERY KILOWH USED BY THE HEAT PUMPS CAN SUPPLY 3 KILOWH OF HEAT FOR SERVICE PURPOSES. MILK COOLING BY ATMOSPHERIC AIR IN THE WINTER IN NORTHERN REGIONS APPEARS TO BE PROMISING.

Details

  • Original title: [In Russian. / En russe.]
  • Record ID : 1986-0708
  • Languages: Russian
  • Source: Kholodilnaya Tekhnika - n. 9
  • Publication date: 1984
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (106)
See the source