Summary
The performances of a refrigeration cycle of a HFC-152a/HFC-125 mixture used as a refrigerant for household refrigerators were calculated and analyzed in detail. The results of the theoretical analysis indicate that the HFC-152a/HFC-125 mixture in the composition of 0.85 mass fraction of HFC-152a has a similar refrigeration performance with the existing refrigerant CFC-12. The experimental results indicate that the refrigeration performances of the domestic refrigerator charged with the new refrigerant can meet the requirement of the National Standard of China, under the appropriate proportion and the optimum charge amount. In conclusion, the mixing refrigerant HFC-152a/HFC-125 proposed in this study seems to be an appropriate long term candidate to replace CFC-12 as a new generation refrigerant of domestic refrigerators, because of its well environmentally acceptable properties and its favourable refrigeration performances.
Details
- Original title: Testing of the mixing refrigerants HFC-152a/HFC-125 in a domestic refrigerator.
- Record ID : 2005-2597
- Languages: English
- Subject: Regulation
- Source: Applied Thermal Engineering - vol. 25 - n. 8-9
- Publication date: 2005/06
Links
See other articles in this issue (6)
See the source
Indexing
-
Themes:
HFCs;
Blends;
Domestic applications (refrigerators, freezers);
Industrial, commercial and domestic refrigeration: regulations and standards;
Refrigerants, secondary refrigerants: regulations and standards;
Refrigerating equipment: regulations and standards - Keywords: Standardization; Comparison; China; Measurement; Household refrigerator; R152a; R125; Performance; Mixture; Expérimentation; Refrigerant
-
Test standards for household refrigerators and ...
- Author(s) : BANSAL P. K., KRUGER R.
- Date : 1995/01
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 18 - n. 1
- Formats : PDF
View record
-
Household refrigerating appliances. Refrigerato...
- Date : 1996
- Languages : French
- Source: Proj. Amend. ISO/Draft Amend. ISO - ISO 7371:1995-DAM 1; 7 p.; 2 tabl.
View record
-
Method of testing closed refrigerators. Public ...
- Author(s) : ASHRAE
- Date : 1999/08
- Languages : English
- Source: ASHRAE Stand. - BSR-ASHRAE 117-1992R; 14 p.; 2 ref.
View record
-
Household refrigerating appliances. Refrigerato...
- Date : 1995/11/15
- Languages : French
- Source: Norme int. ISO/Int. Stand. ISO - ed. 2; ISO 7371:1995; 49 p. (F) + 47 p. (E); 19 fig.; 4 tabl.; 4 ref.; 2 append.
View record
-
Household frost-free refrigerating appliances. ...
- Date : 1995/11/15
- Languages : French
- Source: Norme int. ISO/Int. Stand. ISO - ISO 8561:1995; 53 p. (F); 51 p. (E); 20 fig.; 5 tabl.; 4 ref.; 2 append.
View record