Summary
Taking the measured water temperature of buried pipe in a typical summer condition for example, according to Fourier series approximation algorithms and sampling theorem, determines the minimum number of test points to restore the outlet water temperature fluctuation profile during the entire summer running process, and presents the seasonal performance testing method for ground-source heal pump systems. The results show that the water temperature profile of buried pipe during the entire summer running process can be restored by uniformly testing outlet water temperature four times, and by using second order harmonic Fourier series, the restored results and the measured results are in good agreement. Through magnifying the phase of second order harmonic Fourier series by 2. 3 times, the restored error can be reduced to ± 1%.
Available documents
Format PDF
Pages: 76-80
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: [In Chinese. / En chinois.]
- Record ID : 30014069
- Languages: Chinese
- Source: HV & AC - vol. 44 - n. 294
- Publication date: 2014/09
Links
See other articles in this issue (4)
See the source
Indexing
- Themes: Heat pumps techniques
- Keywords: Fourier; Temperature; Ground; Heat pump; Performance; Model; Water
-
Influence of soil temperature field on the heat...
- Author(s) : WANG J., XU Y., MAO J.
- Date : 2009/03
- Languages : Chinese
- Source: HV & AC - vol. 39 - n. 222
- Formats : PDF
View record
-
Thermal modelling of groundwater heat pump with...
- Author(s) : NI L., JIANG Y., YAO Y., et al.
- Date : 2007/08/21
- Languages : English
- Source: ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
View record
-
Ground heat balance in GSHP.
- Author(s) : MA H., LONG W.
- Date : 2007/08/21
- Languages : English
- Source: ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
View record
-
Cooling water temperature difference of open-lo...
- Author(s) : GAO W., WANG H.
- Date : 2013/03
- Languages : Chinese
- Source: HV & AC - vol. 43 - n. 275
- Formats : PDF
View record
-
Influence of natural convection in water-filled...
- Author(s) : GUSTAFSSON A. M.
- Date : 2008/01/19
- Languages : English
- Source: ASHRAE Transactions. 2008 Winter Meeting, New York City, NY. Volume 114, part 1 + CD-ROM.
View record