Two-fluid modelling of inverted annular film boiling.
Author(s) : HAMMOUDA N., GROENEVELD D. C., CHENG S. C.
Type of article: Article
Summary
Comparisons between the two-fluid model predictions and experimental data from four fluids resulted in overall root-mean-square errors of 14.90, 5.67, 6.58 and 6.19% with the data of water, R12, R22 and R134a, respectively.
Details
- Original title: Two-fluid modelling of inverted annular film boiling.
- Record ID : 1998-0146
- Languages: English
- Source: International Journal of Heat and Mass Transfer - vol. 40 - n. 11
- Publication date: 1997/07
Links
See the source
Indexing
- Themes: Mass transfer
- Keywords: R134a; Measurement; Tube; Heat transfer; R22; R12; Modelling; Film; Boiling; Water
-
Nucleate pool boiling data for five refrigerant...
- Author(s) : WEBB R. L., PAIS C.
- Date : 1992/08
- Languages : English
- Source: International Journal of Heat and Mass Transfer - vol. 35 - n. 8
View record
-
A SOLUTION FOR DISPERSED FLOW HEAT TRANSFER USI...
- Author(s) : YODER G. L. Jr, ROHSENOW W. M.
- Date : 1983/02
- Languages : English
- Source: J. Heat Transf. - vol. 105 - n. 1
View record
-
Forced convective heat transfer of R22 evaporat...
- Author(s) : OUAZIA B., MARVILLET C., FEIDT M.
- Date : 1994/05
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 17 - n. 4
- Formats : PDF
View record
-
HEAT TRANSFER WITH BOILING OF R12 AND R22 IN NA...
- Author(s) : KORNEEV A. D.
- Date : 1983
- Languages : Russian
- Source: Kholodilnaya Tekhnika - n. 2
View record
-
Saturated flow boiling heat transfer in interna...
- Author(s) : WEN M. Y., HSIEH S. S.
- Date : 1995/02
- Languages : English
- Source: J. Heat Transf. - vol. 117 - n. 1
View record