Airflow inside school building office compartments with moderate environments.
Author(s) : CONCEIÇÃO E. Z. E., VICENTE V. D. S. R., LÚCIO M. J. R.
Type of article: Article
Summary
In this paper, the airflow inside school building office compartments with moderate environments, in steady-state conditions, is experimentally and numerically analyzed. The experimental tests are made in a developed experimental chamber, while the numerical results are obtained in a developed numerical model. The air velocity fluctuations are experimentally measured and the air velocity root mean square, the air turbulence intensity, the draft risk, the air velocity fluctuation frequencies, and the air velocity fluctuation equivalent frequencies are calculated. The mean and local air renovation rates, using the decay tracer gases method with a carbon dioxide concentration, are calculated. The three-dimensional air velocity and the air renovation rate are numerically calculated. Both these experimental and numerical results are compared to better understand the airflow topology inside this kind of compartment and evaluate the comfort level, namely the thermal comfort, local thermal discomfort, and air quality levels, to which occupants are subjected. The analyzed airflow topology, with the air forced inlet and outlet located above the occupants' head level, is divided into two areas: the non-occupied upper area, which contains the airflow inlet and outlet, with high air velocity levels, is developed to facilitate the contaminant extraction released by the occupants, while the occupied lower area, with low air velocity levels, is developed to ensure good thermal comfort and reduced local discomfort levels, with the capacity to transport the occupants' contaminants to the upper area.
Details
- Original title: Airflow inside school building office compartments with moderate environments.
- Record ID : 2008-1765
- Languages: English
- Source: HVAC&R Research - vol. 14 - n. 2
- Publication date: 2008/03
Links
See other articles in this issue (6)
See the source
Indexing
- Themes: Indoor air quality
- Keywords: Velocity (fluids, gases); Office; CFD; Air quality; Air; Simulation; Expérimentation; Flow; School; Air conditioning
-
Comparison of displacement and mixing diffusers.
- Author(s) : JIANG Z., et al.
- Date : 1992/09
- Languages : English
- Source: Indoor Air - vol. 2 - n. 3
View record
-
Field evaluation of thermal comfort and indoor ...
- Author(s) : WANG F., LEE M., CHENG T., et al.
- Date : 2012/08
- Languages : English
- Source: HVAC&R Research - vol. 18 - n. 4
View record
-
Experimental evaluation of local values of air ...
- Author(s) : CANNISTRARO G., GIACONIA C., RIZZO G.
- Date : 1992/12
- Languages : Italian
- Source: Cond. Aria - vol. 36 - n. 12
View record
-
Numerical simulation of thermal environment at ...
- Author(s) : FEČER T., HATTEN T. S. , BI Y., CAO G.
- Date : 2021/12
- Languages : English
- Source: REHVA Journal - vol. 58 - n. 6
- Formats : PDF
View record
-
Study on design method of commercial kitchen ve...
- Author(s) : OGITA S., KONDO Y., FUJITA M., et al.
- Date : 2014/10
- Languages : Japanese
- Source: Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan - n. 211
View record