IIR document
Assessment of energy efficiency and operating performance of refrigerating systems in a supermarket.
Number: 1186
Author(s) : HUDJETZ S., KOHLER P., BECKER M.
Summary
Differently sized real-world refrigerating systems have been prepared to assess their energy efficiency using monitoring data. In a previous paper, these field sites have been introduced in a compact form. Furthermore, preliminary results for one of these field sites – a supermarket in Germany – have been shown. In the present paper, results from further analysis of this supermarket are given. Special attention has been turned on the operating performance of one of two parallel racks for medium temperature refrigeration (R134a as refrigerant) which is coupled to the parallel rack for low temperature refrigeration (CO2 as refrigerant) via a setup of multiple heat exchangers. Collected data are evaluated according to German specification VDMA 24247-7 using an indirect analysis method based on compressor polynomials. The results demonstrate the applicability of the selected indirect method and highlight the necessary next steps.
Available documents
Assessment of energy efficiency and operating performance of refrigerating systems in a supermarket
Pages: 6
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Assessment of energy efficiency and operating performance of refrigerating systems in a supermarket.
- Record ID : 30027930
- Languages: English
- Subject: Technology, HFCs alternatives
- Source: 14th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2020). Proceedings. Kyoto, Japon, December 7-9th 2020.
- Publication date: 2020/12/07
- DOI: http://dx.doi.org/10.18462/iir.gl.2020.1186
Links
See other articles from the proceedings (120)
See the conference proceedings
Indexing
-
Themes:
Supermarkets, display cabinets;
CO2;
HFCs;
Compressors - Keywords: COP; CO2; Supermarket; R134a; Indirect system; Compressor; Energy efficiency; Case study; Germany; R744
-
Applications of the SuperSmart energy-benchmark...
- Author(s) : FIDORRA N., HAFNER A., MINETTO S., et al.
- Date : 2014/08/02
- Languages : English
- Source: 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
View record
-
Evaluation of system options and refrigerants f...
- Author(s) : WINANDY E., HUNDY G.
- Date : 2012/02/22
- Languages : English
- Source: CYTEF 2012. VI Congreso Ibérico y IV Congreso Iberoamericano de Ciencias y Técnicas del Frío, Madrid, España, 22-24 de febrero, 2012.
- Formats : PDF
View record
-
Comportamiento energético de una instalación fr...
- Author(s) : SÁNCHEZ D., LLOPIS R., CATALÁN-GIL J., et al.
- Date : 2018/06/19
- Languages : Spanish
- Source: CYTEF 2018. IX Congreso Ibérico y VII Congreso Iberoamericano de Ciencias y Técnicas del Frío, Valencia, España, 19-21 junio 2018.
- Formats : PDF
View record
-
Energy analysis of CO2 refrigeration systems us...
- Author(s) : DUGARIA S., CALABRESE L., AZZOLIN M., et al.
- Date : 2018/06/18
- Languages : English
- Source: 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
View record
-
Monitoring of a CO2 commercial refrigeration sy...
- Author(s) : DUGARIA S., AZZOLIN M., CALABRESE L., et al.
- Date : 2019/08/24
- Languages : English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
View record