IIR document

CO2 supermarket refrigeration systems for southeast Asia and the USA.

Number: pap. ID105

Author(s) : SHARMA V., FRICKE B., BANSAL P.

Summary

This paper presents a comparative analysis of the annual energy consumption of CO2 refrigeration systems in eighty eight cities from all climate zones in Southeast Asia. Also, the performance of the CO2 refrigeration systems is compared to the baseline R-404A multiplex direct expansion (DX) system. Finally, the overall performance of the CO2 refrigeration systems in various climatic conditions in Southeast Asia is compared to that in the United States. For the refrigeration systems investigated, it was found that the Transcritical Booster System with Bypass Compressor (TBS-BC) performs better or equivalent to the R-404A multiplex DX system in the northern regions of Southeast Asia (China and Japan). In the southern regions of Southeast Asia (India, Bangladesh, Burma), the R-404A multiplex DX and the Combined Secondary Cascade (CSC) systems perform better than the TBS-BC.

Available documents

Format PDF

Pages: 8 p.

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: CO2 supermarket refrigeration systems for southeast Asia and the USA.
  • Record ID : 30012536
  • Languages: English
  • Source: 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
  • Publication date: 2014/08/02

Links


See other articles from the proceedings (119)
See the conference proceedings