Summary
Liquid-separation condensation is a novel technology to enhance the condenser performance. Four liquid-separation condensers (LSCs) that had the only difference in refrigerant circuitry were designed, and they were respectively installed to the air-conditioning system and experimentally studied. The capillary tube length and the refrigerant charge were adjusted to achieve the optimum energy efficiency ratio (EER) for each system. The cooling capacity, the system power input and EER were compared at the optimum point. It is found that the four systems are most distinguished in LSCs in terms of condensing pressure and subcooling because of different refrigerant circuitries. The exergy analysis was also carried out. The results show that the refrigerant circuity in LSC has great impacts on the exergetic performance of all system components, and the order of highest exergy efficiency of the four systems is different from that of EER. The detailed characteristics of the four LSCs were further discussed at the designing condition and the practical condition in the tests. The pressure drop of LSC is dominated by the last pass that has serpentine tubes. It is concluded that a low penalty factor (PF) in LSC does not guarantee the good system performance. The optimization of refrigerant circuitry in the condenser to improve the system efficiency should use the system performance as the objective at the system level instead of PF.
Available documents
Format PDF
Pages: 154-164
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Comparative performance of air-conditioning systems with different refrigerant circuitries in liquid-separation condenser.
- Record ID : 30024308
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 92
- Publication date: 2018/08
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2018.05.031
Links
See other articles in this issue (21)
See the source
-
Method and apparatus for controlling evaporator...
- Author(s) : IOSIFESCU C.
- Date : 2002
- Languages : English
- Source: Ann. Univ. Dunarea Jos Galati, IV - vol. 16
View record
-
Notwendige Eigenschaften der Kältemittel für di...
- Author(s) : HUELLE Z. R.
- Date : 2004/06
- Languages : German
- Source: KI Luft Kältetech. - vol. 40 - n. 6
View record
-
Koudesystemen met natuurlijke circulatie.
- Date : 2004/06
- Languages : Dutch
- Source: Koude & Luchtbehandeling - vol. 97 - n. 6
View record
-
Perspectives of aluminium as a construction mat...
- Author(s) : FLOHR F., MEURER C., SWIDERSKY H. W., et al.
- Date : 2000/07/25
- Languages : English
- Source: Proceedings of the 2000 International Refrigeration Conference at Purdue.
View record
-
Les mesures : sous-refroidissement. Fiche prati...
- Author(s) : JACQUARD P.
- Date : 1998/05
- Languages : French
- Source: La revue pratique du froid et du conditionnement d'air - n. 857
View record