Comparison of performances between R404A and AZ50 used in commercial refrigeration.
Author(s) : CLODIC D.
Summary
A test bench has been developed consisting in an open display-case and a refrigerating system composed mainly of four hermetic compressors, an air cross-current condenser and an evaporator. The evaporating temperature of -40 deg C allows to keep the temperature of the products at -18 deg C for a room temperature of 25 deg C and a relative humidity of 50%. The test bench is designed in order to acquire data on temperatures in the core of products, of blowing air, returned air, air in the room, at the surface of the evaporator, at the surface of the condenser and of the compressors (suction, discharge, oil), etc. A testing method was defined to allow comparison of performances between R404A and AZ50 with respect to refrigerating capacity, energy efficiency as well as preservation of inner temperature of products laying into the display case.
Details
- Original title: Comparison of performances between R404A and AZ50 used in commercial refrigeration.
- Record ID : 1995-0795
- Languages: English
- Source: Proceedings of the 1994 International Refrigeration Conference at Purdue.
- Publication date: 1994/07/19
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (73)
See the conference proceedings
Indexing
-
Themes:
HFCs;
Supermarkets, display cabinets;
Blends - Keywords: Test rig; Refrigerating system; R143a; R134a; Comparison; Commercial application; Display cabinet; R404A; R125; Performance; Mixture; Refrigerant
-
Laboratory evaluation of R407H for commercial r...
- Author(s) : RYDKIN I., OHKUBO S., ARIMOTO H., et al.
- Date : 2018/07/09
- Languages : English
- Source: 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Mezclas HFC/HFO para sustituir al R404A en refr...
- Author(s) : MOTA BABILONI A., BARRAGÁN-CERVERA A., NAVARRO-ESBRÍ J., et al.
- Date : 2016/05/03
- Languages : Spanish
- Source: CYTEF 2016. VIII Congreso Ibérico y VI Congreso Iberoamericano de las Ciencias y Técnicas del Frío, Coimbra-Portugal, 3-6 mayo, 2016.
- Formats : PDF
View record
-
The R125-R290-R134a mixture as a substitute for...
- Author(s) : CAMPORESE R., BIGOLARO G., SCATTOLINI M., BOBBO S.
- Date : 1993/11/15
- Languages : English
- Source: Cold Chain Refrigeration Equipment by Design.
- Formats : PDF
View record
-
System drop-in tests of refrigerant blend R125-...
- Author(s) : SNELSON W. K., LINTON J. W., TRIEBE A. R., HEARTY P. F.
- Date : 1995/01
- Languages : English
- Source: ASHRAE Transactions.
View record
-
Long term viability of R-513A in a stationary r...
- Author(s) : MEDINA J., HUGHES J., COOMBS R.
- Date : 2019/08/24
- Languages : English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
View record