IIR document

The R125-R290-R134a mixture as a substitute for R502 in commercial refrigeration.

Summary

The possibility of using the R125-R290-R134a mixture to replace R502 has been studied. The performance of this mixture has been calculated assuming -25 deg C at the evaporator inlet and a 45 deg C dew-point temperature at the condenser. Compositions that ensure a performance very similar to that of R502 are: R125 = 50-70; R290 = 5-10; R134a = 20-45. Five different mixtures have been tested in a refrigerated display cabinet. The results of these tests confirm that this mixture could be a good substitute for R502.

Available documents

Format PDF

Pages: 1993-3

This document is to be digitised and will be available within 10 working days

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: The R125-R290-R134a mixture as a substitute for R502 in commercial refrigeration.
  • Record ID : 1994-3501
  • Languages: English
  • Source: Cold Chain Refrigeration Equipment by Design.
  • Publication date: 1993/11/15
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles from the proceedings (59)