Determination of dielectric properties of refrigerants.

Author(s) : GBUR A. M.

Summary

The electrical properties of dielectric constant, dissipation factor, and breakdown voltage were determined for R11, R12, R22, R32, R123, R124, R125, R134a, R143a, R236fa, R245fa, R404A, R407C, R410A, R507A, R508A, and R508B. All measurements were made at 25°C.

Details

  • Original title: Determination of dielectric properties of refrigerants.
  • Record ID : 2006-1625
  • Languages: English
  • Source: ASHRAE Transactions. 2005 Winter Meeting. Volume 111, part 1 + CD-ROM.
  • Publication date: 2005

Links


See other articles from the proceedings (45)
See the conference proceedings