IIR document
Energy and exergy analysis of a two-stage cascade vapor compression refrigeration system with modified system configuration.
Author(s) : PATILUNA D. N. G., DONASCO E. A. A., HERNANDEZ N. M., MAMALIAS J. B. A., VIÑA R. R.
Type of article: IJR article
Summary
This study proposes a modification to the two-stage cascade vapor compression refrigeration system by adding internal heat exchangers that function as subcoolers and desuperheater. The influence of each internal heat exchanger proposed on the exergy destruction rate, exergy efficiency, compressor power consumption, ECOP, and COP of the system was investigated. Additionally, various refrigerant combinations were considered as working fluids to evaluate which combination is the most suitable for the proposed system. Mathematical models based on the principles of thermodynamics were established in Engineering Equation Solver (EES), a software used for energy and exergy analysis. The results reveal that the addition of specific internal heat exchangers causes either an increase or decrease in overall system performance, depending on the type of refrigerant combination used. Consequently, there exists an optimal system configuration for each refrigerant combination. Compared with the conventional two-stage cascade refrigeration system, the optimal system configurations in the present study exhibited higher overall system performance. A maximum increase in exergy efficiency, ECOP, and COP of 7.31 %, 9.8 %, and 7.3 %, respectively, can be observed with the refrigerant combination R450A/R404A. Additionally, the results of the exergy analysis identify that the HTC compressor, condenser, LTC compressor, and cascade condenser are the primary contributors to the exergy destruction rate within the system.
Available documents
Format PDF
Pages: 33-54
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Energy and exergy analysis of a two-stage cascade vapor compression refrigeration system with modified system configuration.
- Record ID : 30033206
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 169
- Publication date: 2025/01
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2024.10.013
Links
See other articles in this issue (33)
See the source
Indexing
-
The performance comparison of a two-stage compr...
- Author(s) : BAE K., KWAK M., KANG B., et al.
- Date : 2010/06/07
- Languages : English
- Source: ACRA2010. Asian conference on refrigeration and air conditioning: Tokyo, Japan, June 7-9, 2010.
- Formats : PDF
View record
-
A literature review of numerical modeling techn...
- Author(s) : SARFRAZ O., BACH C. K., BRADSHAW C. R.
- Date : 2018/07/09
- Languages : English
- Source: 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Graph-based dynamic modeling of two-phase heat ...
- Author(s) : RUSSEL K. M., AKSLAND C. T., ALLEYNE A. G.
- Date : 2022/05
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 137
- Formats : PDF
View record
-
Performance analysis and multi-objective optimi...
- Author(s) : KHERA R., ARORA A., ARORA B. B.
- Date : 2023/10
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 154
- Formats : PDF
View record
-
Scambiatori di calore ad aria per cicli frigori...
- Author(s) : LOZZA G., PERFETTI C.
- Date : 2003
- Languages : Italian
- Source: Industria & Formazione - vol. 27 - n. 274
View record