Experimental investigation on capillary tube for a domestic freezer with a mixture of R290/R600a (50/50) as a substitute for R134a.

Number: pap. n. 4.2

Author(s) : HUAN Z., BOLAJI B. O.

Summary

The hydrocarbon mixture of R290/R600a (HCs) with a mass ratio of 50/50 is regarded as a promising long-term refrigerant to replace R134a in domestic freezers. Due to the property difference between R134a and HCs, the actual length of the capillary tube should be renewed suitable for this alternative mixture; otherwise, the freezer system may have lower thermal performance than the R134a system. During the investigation a domestic freezer of 150 L was used to evaluate the inner temperature distribution and the thermodynamic cycle performances of R290/R600a (50/50) under conditions with different lengths of the capillary tube. The experimental results indicate that the R290/R600a (50/50) mixture with the optimized capillary length, which was obtained from the simulation, offers higher energy efficiency with a lower discharge temperature than the original R134a system. The proposed mixture is proven to be a suitable long-term alternative in terms of its excellent thermodynamic cycle performances.

Available documents

Format PDF

Pages: 8 p.

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Experimental investigation on capillary tube for a domestic freezer with a mixture of R290/R600a (50/50) as a substitute for R134a.
  • Record ID : 30006066
  • Languages: English
  • Source: 4th Jordanian IIR International Conference on Refrigeration and Air Conditioning. Proceedings: Amman, Jordan, September 10-12, 2012.
  • Publication date: 2012/09/10