Experimental investigation on condensation performance of fin-and-flat-tube heat exchanger.

Author(s) : LIANG X., XING S., ZHUANG R., et al.

Summary

Condensation heat transfer performance of a louvered fin-and-flat-tube heat exchanger (FTHX) in single slab and in residential air-conditioning system were experimentally investigated, and were compared with fin-and-circular-tube heat exchangers (CTHX) under the same testing conditions. The test results showed that: FTHX had the characteristics of low pressure drop of air side, high pressure drop of refrigerant side and less refrigerant charge; the overall heat transfer performance of copper FTHX was higher than that of diameter 7 mm CTHX but a little lower than that of diameter 9.52 mm CTHX; the cooling capacity and EER of the residential air-conditioning system with FTHX were a little lower than those of the system with diameter 9.52 mm CTHX.

Available documents

Format PDF

Available

  • Public price

    20 €

  • Member price*

    15 €

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Experimental investigation on condensation performance of fin-and-flat-tube heat exchanger.
  • Record ID : 2010-1795
  • Languages: English
  • Publication date: 2010/07/12
  • Source: Source: Proc. 2010 int. Refrig. Air Cond. Conf., Purdue Univ.
    n. 2150; 5 p.; fig.; photogr.; tabl.; 2 ref.