Experimental investigation on the effect of mixing length on the performance of two-phase ejector for CO2 refrigeration cycle with and without heat exchangers.
Investigación experimental sobre el efecto de la longitud de mezcla en el rendimiento del eyector bifásico para el ciclo de refrigeración del CO2, con y sin intercambiador de calor.
Author(s) : NAKAGAWA M., MARASIGAN A. R., MATSUKAWA T., et al.
Type of article: Article
Summary
In ejector systems using the promising natural refrigerant CO2, the mixing of high speed two-phase primary flow and suction vapour is crucial in designing an efficient ejector. In this study, the effect of mixing length on ejector system performance was analyzed experimentally. The mixing lengths used were 5, 15 and 25 mm, with constant rectangular cross-section. The experiments were performed for both ejector and conventional expansion systems with and without internal heat exchanger. The gas cooler pressure (9-10.5 MPa), evaporator temperature (2-8°C), and gas cooler outlet temperature (41-44°C) were varied for each type. The results showed the significant effect of mixing length in ejector's performance. The 15 mm-type provided the highest pressure recovery, entrainment ratio and COP in all the conditions used in this research. A maximum COP improvement of up to 26% compared to similar conventional system was obtained.
Available documents
Format PDF
Pages: 46-54 (8 p.)
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Investigación experimental sobre el efecto de la longitud de mezcla en el rendimiento del eyector bifásico para el ciclo de refrigeración del CO2, con y sin intercambiador de calor.
- Record ID : 30003147
- Languages: Spanish
- Source: Frío Calor Aire acondicionado - vol. 39 - n. 441
- Publication date: 2011/11
Links
- See translations: Experimental investigation on the effect of mixing length on the performance of two-phase ejector for CO2 refrigeration cycle with and without heat exchangers.
See other articles in this issue (6)
See the source
-
Experimental analysis on the effect of internal...
- Author(s) : NAKAGAWA M., MARASIGAN A. R., MATSUKAWA T.
- Date : 2011/11
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 7
- Formats : PDF
View record
-
Investigación en laboratorio de diferentes geom...
- Author(s) : HAFNER A., LADAM Y., ANDRESEN T., et al.
- Date : 2011/09
- Languages : Spanish
- Source: Frío Calor Aire acondicionado - vol. 39 - n. 439
- Formats : PDF
View record
-
Improving the performance of transcritical CO2 ...
- Author(s) : LIU F., GROLL E. A.
- Date : 2008
- Languages : English
- Source: IEA HPC Newsl. - vol. 26 - n. 4
View record
-
Theoretical evaluation on effect of internal he...
- Author(s) : MA Y. T., WANG H. L., ZHANG Z. Y., et al.
- Date : 2013/01
- Languages : English
- Source: Applied Thermal Engineering - vol. 50 - n. 1
View record
-
Experimental comparison of cycle modifications ...
- Author(s) : TOFFOLETTI G., BARTA R. B., GRAJALES S. M., LIU H., ZIVIANI D., GROLL E. A.
- Date : 2025/01
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 169
- Formats : PDF
View record