EXPERIMENTAL RESEARCH OF HIGH-TEMPERATURE COMPOSITION CHANGEABLE CIRCUIT USING ALTERNATIVE MIXTURES.

[In Japanese. / En japonais.]

Author(s) : YOSHIDA Y.

Type of article: Article

Summary

FOUR KINDS OF NON-AZEOTROPIC MIXTURES R22-R134A, R22-142B, R22-R152A AND R22-R123, WERE EVALUATED IN ORDER TO REALIZE HIGHER CONDENSING TEMPERATURE THAN THAT USING R22 AT HIGH TEMPERATURE OPERATION, AND LARGER HEATING CAPACITY THAN THAT USING R22-R114 AT NORMAL TEMPERATURE OPERATION. ISOTHERMAL VAPOUR-LIQUID EQUILIBRIUM FOR SOME OF THESE MIXTURES WAS MEASURED BY THE STATIC METHOD. AS A RESULT, THE COMPOSITION CHANGEABLE HIGH-TEMPERATURE HEAT PUMP INDICATED THE MOST EFFECTIVE CHARACTERISTICS WHEN USING R22-R142B AS THE REFRIGERANT.

Details

  • Original title: [In Japanese. / En japonais.]
  • Record ID : 1991-2275
  • Languages: Japanese
  • Source: Trans. JAR - vol. 7 - n. 3
  • Publication date: 1990
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (5)
See the source