Numerical analysis of thermal comfort parameters in an office: zonal and CFD model comparison.
Author(s) : WOLF I., VILICIC I., FRANKOVIC B., et al.
Summary
Zonal and computational fluid dynamics (CFD) modelling approaches for simulation of airflows and evaluation of thermal comfort parameters inside an enclosure have been compared in the paper in the case of an office. The steady-state 3D CFD model has been built using a commercial CFD code fluent that is based on the finite volume method. Different turbulence models integrated in Fluent have been tested. The results obtained by the CFD model have been compared to the zonal model and experimental results, both obtained at the Research and Development Centre of the CIAT factory. A correct compatibility between the results has been found.
Available documents
Format PDF
Pages: 489-500
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Numerical analysis of thermal comfort parameters in an office: zonal and CFD model comparison.
- Record ID : 2009-2140
- Languages: English
- Source: Energija i okolis 2008. Medunarodni kongres: XXI. znanstveni skup o energiji i zastiti ikolisa./ Energy and the environment 2008. International congress: 21th Scientific Conference on Energy and the Environment.
- Publication date: 2008/10/22
Links
See other articles from the proceedings (18)
See the conference proceedings
Indexing
- Themes: Comfort air conditioning
- Keywords: Office; CFD; Air; Simulation; Flow; Thermal comfort; Air conditioning
-
CFD analysis of a call centre HVAC system: a ca...
- Author(s) : ADHIKARY P., BANDYOPADHYAY S., MAZUMDAR A.
- Date : 2018/07/27
- Languages : English
- Source: Proceedings of the International Conference on Emerging Technologies for Sustainable and Intelligent HVAC&R Systems, Kolkata, July 27-28 2018.
- Formats : PDF
View record
-
Efficient coupling of multizone and CFD indoor ...
- Author(s) : KHALIFA H. E., ELHADIDI B., DANNENHOFFER J. F.
- Date : 2007/06/23
- Languages : English
- Source: ASHRAE Transactions. 2007 Annual Meeting, Long Beach, CA. Volume 113, part 2 + CD-ROM.
View record
-
Occupancy based cooling using multi-split syste...
- Author(s) : LO L. J., NOVOSELAC A.
- Date : 2009/05/20
- Languages : English
- Source: ACRA-2009. The proceedings of the 4th Asian conference on refrigeration and air conditioning: May 20-22, 2009, Taipei, R.O.C.
- Formats : PDF
View record
-
The numerical simulation of an air-conditioned ...
- Author(s) : CHEN X., REN X., TIE Z.
- Date : 2007/08/21
- Languages : English
- Source: ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
View record
-
Thermal climate assessment in office environmen...
- Author(s) : NILSSON H., HOLMÉR I., HOLMBERG S., et al.
- Date : 2000/07/09
- Languages : English
- Source: Air distribution in rooms: ventilation for health and sustainable environment. Roomvent 2000. Proceedings of the 7th international conference.
View record