Summary
In this study, the performance of a multi-split VRF system using the bypass cycle and injection cycle is evaluated using the numerical simulation as a possible sub-cooling method to prevent flash gas generation in liquid pipelines. The simulation for the multi-split VRF system is developed by considering the applications of the bypass cycle and injection cycle, and is validated with experimental data. The bypass cycle and injection cycle in the multi-split VRF system yield improvements in their cooling capacities of the order of 3.22% and 13.43%, respectively, and energy efficient ratio (EER) of the order of 1.98% and 1.72%, respectively. The input power of the injection cycle is reduced by up to 4.45% when the performance of the multi-split VRF systems with bypass cycle and injection cycle is compared under the same cooling capacity conditions.
Available documents
Format PDF
Pages: 202-213
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Performance comparison between bypass cycle and injection cycle for sub-cooling methods in multi-split variable refrigerant flow (VRF) system in hot seasons.
- Record ID : 30026978
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 107
- Publication date: 2019/11
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2019.07.010
Links
See other articles in this issue (32)
See the source
-
Numerical study on performance comparison for s...
- Author(s) : LEE T., MIN B., CHOI G.-M., et al.
- Date : 2019/08/24
- Languages : English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
View record
-
Numerical investigation on effects of sub-cooli...
- Author(s) : MIN B. C., NA S., KIM H., et al.
- Date : 2018/07/09
- Languages : English
- Source: 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Experimental study on multi-split air condition...
- Author(s) : TU Q., DONG K. J., ZOU D., et al.
- Date : 2011/10
- Languages : English
- Source: Applied Thermal Engineering - vol. 31 - n. 14-15
View record
-
Modeling of variable refrigerant flow system fo...
- Author(s) : KWON L., HWANG Y., RADERMACHER R., et al.
- Date : 2012/07/16
- Languages : English
- Source: 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Indoor unit fault detector for a multi-split VR...
- Author(s) : SHI Y., KARNG S. W., KIM S. Y.
- Date : 2014/04
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 40
- Formats : PDF
View record