PRACTICAL TECHNIQUES FOR COOLING BIOLOGICAL SAMPLES AT 0.3-100 K/MIN.

Author(s) : DIAPER M. P.

Type of article: Article

Summary

THE RATE OF HEAT TRANSFER FROM A LIQUID MEDIUM THAT SURROUNDED THE SAMPLES, INTO LIQUID NITROGEN, WAS VARIED BY CHANGING THE INSULATING PROPERTIES OF THE CONTAINER WALL. THIS WAS ACHIEVED BY USING EVACUATED OR UNEVACUATED DEWAR FLASKS, AND BY SHUNTING THE VACUUM OR AIR JACKET BY VARIOUS MATERIALS OF HIGHER CONDUCTIVITY. THE MOST RAPID COOLING RATES WERE OBTAINED BY VARYING THE SIZE OF SINGLE-WALLED GLASS VESSELS. ALMOST THE ENTIRE RANGE, FROM 0.3 TO 100 K/MIN, WAS COVERED.

Details

  • Original title: PRACTICAL TECHNIQUES FOR COOLING BIOLOGICAL SAMPLES AT 0.3-100 K/MIN.
  • Record ID : 1987-1617
  • Languages: English
  • Source: Cryo-Letters - vol. 7 - n. 5
  • Publication date: 1986
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (2)
See the source