REFRIGERATION EFFECTIVENESS ABOARD TUNA SEINERS.

Author(s) : COTTRELL R. H., HOYT J. W.

Type of article: Article

Summary

THIS PAPER DISCUSSES THE ADDITION OF AN EXTERNAL HEAT EXCHANGER, CALLED A CHILLER, TO AUGMENT THE REFRIGERATION EFFECT PROVIDED BY THE EXISTING COIL EVAPORATORS LINING THE FISH-WELL BULKHEADS. AVAILABLE DATA ON REFRIGERATION EFFECTIVENESS OF MODERN TUNA SEINERS ARE ANALYSED AND A COMPUTER SIMULATION OF THE SYSTEM IS PRESENTED. OTHER COMPUTER RESULTS DEAL WITH AUGMENTATION OF THE SYSTEM BY THE ADDITION OF REFRIGERATION CAPACITY THROUGH AN EXTERNAL CHILLER. A NEW MODEL FOR THE HEAT TRANSFER INVOLVED IN FREEZING OF FISH IS PRESENTED. (BMT ABSTR., GB., 46, N 8, 1991/08, 91081779.

Details

  • Original title: REFRIGERATION EFFECTIVENESS ABOARD TUNA SEINERS.
  • Record ID : 1992-1218
  • Languages: English
  • Source: Mar. Technol. - vol. 28 - n. 2
  • Publication date: 1991/03
  • Document available for consultation in the library of the IIR headquarters only.

Links