Study on evaporator of carbon-dioxide water source heat pump.

Bomba de calor para dióxido de carbono-agua: estudio sobre el diseño del evaporador tipo inundado.

Author(s) : LI M. X., LI B., YE T. Z., et al.

Type of article: Article

Summary

This article is the Spanish translation of an article presented at the IIR-Gustav Lorentzen conference on natural working fluids, in Copenhagen, Denmark (see the Bulletin of the IIR, reference 2009-0362). For improving the coefficient of performance of carbon-dioxide water-water heat pump effectively, this paper discusses the design of a flooded type evaporator. Several correlations of pool boiling heat transfer are used to calculate the coefficient of carbon dioxide pool boiling heat transfer. An experiment loop was established. The boiling heat transfer of enhanced tube and the smooth were tested respectively. The calculation results are compared with the test results. A proper correlation is recommended for design according to the experimental results. Effect of oil on the flooded evaporator is discussed. A dry evaporator is suggested to combine with the flooded evaporator for oil separation.

Available documents

Format PDF

Pages: pp. 36-41 (5 p.)

Available

  • Public price

    20 €

  • Member price*

    15 €

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Bomba de calor para dióxido de carbono-agua: estudio sobre el diseño del evaporador tipo inundado.
  • Record ID : 2010-0581
  • Languages: Spanish
  • Source: IIF-IIR/Frío Calor Aire acond. - vol. 38 - n. 422
  • Publication date: 2010/02

Links


See other articles in this issue (2)