Testing of a hydrocarbon mixture in domestic refrigerators.

Summary

Performance of a propane/isobutane (R290-R600a) mixture was investigated in domestic refrigerators. Thermodynamic cycle analysis indicated that the R290-R600a mixture in the composition range of 0.2 to 0.6 mass fraction of R290 yields an increase in the COP of 1.7 to 2.4% as compared to R12. The experimental results obtained with the same compressor indicated that the R290-R600a mixture at 0.6 mass fraction of R290 showed a 3 to 4% increase in energy efficiency and a faster cooling rate as compared to R12. The R290-R600a mixture showed a shorter compressor on-time ratio and lower compressor dome temperatures than R12. In conclusion, the proposed hydrocarbon mixture seems to be an appropriate candidate to replace R12 from the viewpoint of energy conservation.

Details

  • Original title: Testing of a hydrocarbon mixture in domestic refrigerators.
  • Record ID : 1997-2025
  • Languages: English
  • Source: ASHRAE Transactions.
  • Publication date: 1996/02/16
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles from the proceedings (38)
See the conference proceedings