IIR document
The effect of lubricant concentration, miscibility, and viscosity on R134a pool boiling.
Author(s) : KEDZIERSKI M. A.
Type of article: Article, IJR article
Summary
This paper presents pool boiling heat transfer data for 12 different R134a/lubricant mixtures and pure R134a on a Turbo-BII™-HP surface. The mixtures were designed to examine the effects of lubricant mass fraction, viscosity, and miscibility on the heat transfer performance of R134a. The magnitude of the effect of each parameter on the heat transfer was quantified with a regression analysis. The mechanistic cause of each effect was given based on new theoretical interpretation and/or one from the literature. The model illustrates that large improvements over pure R134a heat transfer can be obtained for R134a/lubricant mixtures with small lubricant mass fraction, high lubricant viscosity, and a large critical solution temperature (CST). The ratio of the heat flux of the R134a/lubricant mixture to that of the pure R134a for fixed wall superheat was given as a function of pure R134a heat flux for all 12 mixtures. The lubricant that had the largest CST with R134a exhibited the greatest heat transfer: 100%±20% greater than that of pure R134a. By contrast, the heat transfer of the mixture with the lubricant that had the smallest viscosity and the smallest CST with R134a was 55%±9% less than that of pure R134a. High-speed films of the pure and mixture pool boiling were taken to observe the effect of the lubricant on the nucleate boiling.
Available documents
Format PDF
Pages: 348-366
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: The effect of lubricant concentration, miscibility, and viscosity on R134a pool boiling.
- Record ID : 30001906
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 24 - n. 4
- Publication date: 2001/06
Links
See other articles in this issue (4)
See the source
Indexing
-
On the effect of lubricant on pool boiling heat...
- Author(s) : HUNG J-T., CHEN Y. K., CHEN T. Y., et al.
- Date : 2016/07/11
- Languages : English
- Source: 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
ANFIS based evolutionary concept for estimating...
- Author(s) : SAEE A. D., BAGHBAN A., ZAREI F., et al.
- Date : 2018/12
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 96
- Formats : PDF
View record
-
Effect of bulk lubricant concentration on the e...
- Author(s) : KEDZIERSKI M. A.
- Date : 2005/06
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 28 - n. 4
- Formats : PDF
View record
-
Refrigerant- lubricant mixture properties influ...
- Author(s) : HUNG J. T., CHEN Y. K., SHIH H.-K., WANG C. C.
- Date : 2021/05
- Languages : English
- Source: 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Influence of carbon nanotubes on nucleate pool ...
- Author(s) : PENG H., DING G., HU H., et al.
- Date : 2010/12
- Languages : English
- Source: International Journal of thermal Sciences - vol. 49, n. 12 - vol. 49, n. 12
View record