THE INVESTMENT COST, ENERGY USE AND WEIGHT AND QUALITY LOSSES IN LOW TEMPERATURE COLD STORAGE.
INVESTISSEMENTS, CONSOMMATION D'ENERGIE, PERTES DE MASSE ET DE QUALITE EN ENTREPOSAGE FRIGORIFIQUE A BASSE TEMPERATURE.
Author(s) : MLYNARCZYK J.
Summary
IN THE HEAT BALANCE OF A COLD STORE PRIMARY LOSSES AND GENERATED BY THEM SECONDARY LOSSES WERE DISTINGUISHED. TO THE SECOND ONES THE HEAT EQUIVALENT OF THE WORKING FANS AND THE HEAT OF EVAPORATORS DEFROSTING ARE INCLUDED. IN THIS NEW CONCEPT, TO THE PARTICULAR PRIMARY LOSS A CORRESPONDING RELATED SECONDARY LOSS IS ADDED. IT MEANS FOR EACH ITEM OF THIS BALANCE THE TOTAL ENERGY COSTS, WEIGHT AND QUALITY LOSSES ARE CALCULATED. THE REAL COSTS CAUSED BY PARTICULAR PRIMARY LOSSES ARE OBTAINED AND THEY SHOULD BE TAKEN INTO ACCOUNT IN OPTIMIZATION ANALYSIS OF THE TECHNICAL PROJECTS, ENERGY CONSUMPTION, WEIGHT AND QUALITY LOSSES. THE PROPOSED METHOD WILL TEND TO SOME INCREASE OF INVESTMENT COSTS, REDUCTION OF THE ENERGY USE AS WEIGHT AND QUALITY LOSSES.
Available documents
Format PDF
Pages: 25-31
This document is to be digitised and will be available within 10 working days
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: INVESTISSEMENTS, CONSOMMATION D'ENERGIE, PERTES DE MASSE ET DE QUALITE EN ENTREPOSAGE FRIGORIFIQUE A BASSE TEMPERATURE.
- Record ID : 1985-0682
- Languages: French
- Source: [Refrigeration serving humanity]. Proceedings of the XVIth international Congress of Refrigeration.
- Publication date: 1983/08/07
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (542)
See the conference proceedings
Indexing
- Themes: Cold stores: running, control and safety
- Keywords: Heat balance; Energy consumption; Calculation; Weight loss; Optimization; Cold store
-
L'INFORMATIQUE ET LES INSTALLATIONS FRIGORIFIQUES.
- Author(s) : DEFUDE J.
- Date : 1987
- Languages : French
- Source: Rev. gén. Froid - vol. 77 - n. 10
View record
-
THE DESIGN OF REFRIGERATING INSTALLATIONS AND C...
- Author(s) : YOSHINO T.
- Date : 1987
- Languages : Japanese
- Source: Refrigeration - vol. 62 - n. 718
View record
-
A RESEARCH ON THE RELATIONSHIP AMONG OPTIMUM TH...
- Author(s) : YU J. H.
- Date : 1987/08/24
- Languages : English
- Source: Development in refrigeration, refrigeration for development. Proceedings of the XVIIth international Congress of Refrigeration.
- Formats : PDF
View record
-
COLD STORAGE AND LOW TEMPERATURE STORAGE ROOMS.
- Author(s) : TOL C. van
- Date : 1989/09
- Languages : Dutch
- Source: Koude Klim. - vol. 82 - n. 9
View record
-
PRECOOLING TIME FOR COLD STORAGE.
- Author(s) : ZOU G. N.
- Date : 1983/03
- Languages : Chinese
- Source: J. chin. Assoc. Refrig. - n. 1
View record