A validated model for variable-speed multi-chillers to assess different operation modes.

Author(s) : GUTH T., ATAKAN B., SCHÄDLICH S.

Type of article: IJR article

Summary

Environmental protection drives the replacement of environmentally harmful refrigerants with potentially flammable alternatives, necessitating efficient cooling strategies for varying loads. Legislation limits flammable refrigerant charge, leading to the adoption of multi-chiller systems with smaller charges and therefore also smaller loads per chiller. However, operating such systems requires complex strategies, addressable through fast and reliable models. This study presents a semi-empirical model predicting the behaviour of variable-speed multi-chiller systems. The model focuses on predicting cooling capacity and coefficient of performance (COP) for cooling, with input parameters of evaporation and condensation temperatures, and compressor speed. Experimental validation of the parameterized model shows COP predictions within 3 % for a two-module system using R-290 (propane) under different conditions and compressor speeds. The model assesses various operation strategies, including the conventional mode with fewer chiller modules running at high speed, compared to modes where all chillers run but at reduced speeds. Comparing COP values in these modes reveals energy-saving potentials of up to 14.57 % for constant condensation temperatures. Moreover, strategies involving condensation temperature reduction, or a combination with compressor speed reduction are analysed for energy-saving potentials. Reducing the condensation temperature by 3 K results in savings of up to 13.25 % and combined with the compressor speed reduction savings of up to 23.54 % are feasible. These findings emphasize the importance of considering compressor speed when operating multi-chiller systems to maximize energy savings. The presented model effectively evaluates various strategies and implements variable-load control in multi-chiller systems, serving as a valuable tool for optimising energy efficiency and promoting environmentally friendly cooling practices.

Available documents

Format PDF

Pages: 9-27

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: A validated model for variable-speed multi-chillers to assess different operation modes.
  • Record ID : 30032242
  • Languages: English
  • Subject: Technology
  • Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 160
  • Publication date: 2024/04