Application of oil flooded compression with regeneration to a packaged heat pump system.
Number: pap. 2631
Author(s) : YANG B., BLATCHLEY T., BACH C. K., et al.
Summary
The heating capacity and coefficient of performance (COP) of conventional air-source heat pumps decreases towards lower ambient temperatures. In addition, high discharge temperature at the compressor discharge might limit the operation of the heat pump at very low ambient temperatures. Oil injected into the compression chamber at the beginning of the compression process can absorb part of the heat generated during the compression process, which can result in significant reduction of the compressor discharge temperature. Discharge temperature decreases with increasing injected oil mass fraction, especially at low ambient temperatures. Therefore, oil injection allows the application of air-source heat pumps in regions with very low ambient temperatures in winter. Additionally, oil injection decreases the compressor power consumption by providing better sealing and lower friction during the compression process. Furthermore, if oil injection is combined with a regenerative heat exchanger and an oil cooler, the system performance of a vapor compression system can be improved significantly. The work presented in this paper shows the experimental results of a 5-ton (17.6 kW) R410A packaged heat pump which was retrofitted with an oil injected compressor, integrated indoor heat exchanger oil cooler and regenerator. The effect of different oil mass fractions on the system performance was investigated under standard AHRI 210/240 heating test conditions. According to the results, up to 8% system COP improvement was observed compared to the baseline system for all ambient temperatures.
Available documents
Format PDF
Pages: 8 p.
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Application of oil flooded compression with regeneration to a packaged heat pump system.
- Record ID : 30013057
- Languages: English
- Source: 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Publication date: 2014/07/14
Links
See other articles from the proceedings (203)
See the conference proceedings
Indexing
-
Effects of vapor injected compression, hybrid e...
- Author(s) : BACH C. K., GROLL E. A., BRAUN J. E., et al.
- Date : 2014/07/14
- Languages : English
- Source: 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Modelling of split condenser heat pump: optimiz...
- Author(s) : CHRISTENSEN S. W., ELMEGAARD B., MARKUSSEN W. B., et al.
- Date : 2017/05/11
- Languages : English
- Source: 7th Conference on Ammonia and CO2 Refrigeration Technology. Proceedings: Ohrid, North Macedonia, May 11-13, 2017.
- Formats : PDF
View record
-
Design and test of a domestic heat pump with am...
- Author(s) : MONFARED B. A., PALM B.
- Date : 2011/04/14
- Languages : English
- Source: 4th Conference on Ammonia Refrigeration Technology. Proceedings: Ohrid, North Macedonia, April 14-16, 2011.
- Formats : PDF
View record
-
Performance comparison of round tubes finned he...
- Author(s) : ZOUGHAIB A., MORTADA S., KHAYAT F., et al.
- Date : 2014/07/14
- Languages : English
- Source: 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Analytical study on the performance characteris...
- Author(s) : JEON Y., LEE S. H., JUNG J. H., et al.
- Date : 2014/07/14
- Languages : English
- Source: 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record