Effects of intermediate pressure on the heating performance of a heat pump system using R410A vapor-injection technique.

Author(s) : ROH C. W., KIM M. S.

Type of article: Article, IJR article

Summary

Recent heat pumps are actively equipped with a refrigerant vapor-injection technique to acquire better performance in severe operating conditions. In this study, the target system which has an additional expansion valve at the outlet of condenser was presented. The concept of intermediate pressure was generated in the target system. Effects of the intermediate pressure on the heating performance with various injection ratios were measured and analyzed according to the compressor frequencies ranging from 60 to 100 Hz. Unlike conventional vapor-injection cycle, the maximum injection ratio was highly affected by the intermediate pressure. The high intermediate pressure provided high initial heating capacity and COP; but it restricted the available range of vapor-injection within narrow limits. The result indicates that a proper operating strategy is needed for the vapor-injection cycle.

Available documents

Format PDF

Pages: 1911-1921

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Effects of intermediate pressure on the heating performance of a heat pump system using R410A vapor-injection technique.
  • Record ID : 30002283
  • Languages: English
  • Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 8
  • Publication date: 2011/12