IIR document

Changing of thermophysical properties of the real working fluid liquid phase in evaporator.

Summary

This paper addresses the problem of changing the properties of the real working fluid (refrigerant-oil solution) in an evaporator. It was shown that thermophysical properties of the refrigerant-oil solution depends from the value of the fiction superheat. The comparison of the existing correlation for the calculation of the density of R600a/Reniso WF 15A and R245fa/Planetelf ACD 100FY refrigerant-oil solutions with the experimental data have been performed. It is also shown that existing correlations do not demonstrate reliable prediction of the thermophysical properties of the refrigerant-oil solutions.

Available documents

Format PDF

Pages: 2009-6

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Changing of thermophysical properties of the real working fluid liquid phase in evaporator.
  • Record ID : 2009-2245
  • Languages: English
  • Source: Compressors 2009: 7th International Conference on Compressors and Coolants
  • Publication date: 2009/09/02

Links


See other articles from the proceedings (56)