IIR document

Comparison between experimental and numerical results on a 300 Hz thermo-acoustically-driven pulse tube cooler.

Author(s) : ZHU S., DAI W., YU G., et al.

Summary

This article introduces the authors' recent research work on a 300 Hz thermo-acoustically-driven pulse tube cooler. A lowest no-load temperature reaches 79.6 K with the mean pressure and the inlet pressure ratio being 3.96 and 1.21 MPa, respectively. Modifications, which include the value of Nusselt number and the numerical model of calculating the impendence of the inertance tube, are done to improve the numerical program based on the linear thermoacoustic model. Extensive numerical calculations have been done for comparison with experimental results. Dynamic and thermal characteristics of the pulse tube cooler are obtained numerically. By doing this, the authors intend to improve the numerical model for better design in the future.

Available documents

Format PDF

Pages: ICR07-A1-925

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Comparison between experimental and numerical results on a 300 Hz thermo-acoustically-driven pulse tube cooler.
  • Record ID : 2007-2409
  • Languages: English
  • Source: ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
  • Publication date: 2007/08/21