Summary
This work deals with the assessment of the airflow in a food-processing clean room. The flow pattern inside the working area of a pilot scale clean room was numerically investigated using computational fluid dynamics code based on a finite volume formulation. Two versions of the K-epsilon turbulence model were tested: the standard and the RNG version. The analysis of the velocity magnitude does not reveal sensitive differences between them. Moreover, both models well predict the main features of the flow and numerical results agree with experimental measurements. However, a further examination shows that the RNG K-epsilon turbulence model predicts more swirls and more complex trajectories. As the standard K-epsilon model overestimates the turbulent diffusion, the RNG version seems to be more suitable to calculate the airflow in clean rooms. The influence of initial turbulence intensivity is also pointed out. Finally, the study of the airflow below a laminar flow unit confirms that the design of clean rooms can benefit from the numerical approach.
Available documents
Format PDF
Pages: 351-361
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Computation of the airflow in a pilot scale clean room using K-epsilon turbulence models.
- Record ID : 2003-0424
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 25 - n. 3
- Publication date: 2002/05
Links
See other articles in this issue (10)
See the source
Indexing
- Themes: Air conditioning in laboratories and industry
- Keywords: Food; CFD; Design; Clean room; Modelling; Air distribution
-
The influence of furniture and equipment layout...
- Author(s) : CHEONG K. W., DJUNAEDY E.
- Date : 2001
- Languages : English
- Source: Build. Serv. Eng. Res. Technol. - vol. 22 - n. 4
View record
-
Concevoir l'aéraulique grâce à la simulation nu...
- Author(s) : BOUDOUX S.
- Date : 2000/06
- Languages : French
- Source: Salles propres Maîtrise Contamin. - n. 8
View record
-
Analysis of the contaminant distribution in a t...
- Author(s) : YANG J., LI X., YAN Q., et al.
- Date : 2000/07/09
- Languages : English
- Source: Air distribution in rooms: ventilation for health and sustainable environment. Roomvent 2000. Proceedings of the 7th international conference.
View record
-
A propos des salles blanches à gradient de pres...
- Author(s) : DESJARDINS C.
- Date : 2001/09
- Languages : French
- Source: Chaud Froid Plomb. - n. 638
View record
-
Qualitative comparison of air supply systems in...
- Author(s) : HALUPCZOK J., SODEC F.
- Date : 1997/09
- Languages : German
- Source: Tech. Bau - n. 9
View record