Author(s) : SUN D. W.

Summary

Experiments were carried out using vacuum and air blast chilling. In the first experiments, the hams weighing 4.3 to 4.6 kg were packaged in perforated fibrous casing, and in the second experiments, the hams weighing 5.0 to 6.1 kg were placed in elastic netting. These hams were steam cooked and then cooled to the core temperature of 4 °C. The temperature distributions within the hams were automatically recorded by LabVIEW data acquisition software. The results indicated that vacuum cooling reduced the chilling time by several hours. However, the weight loss in chilling was higher with vacuum cooling. It may be possible to offset this by a higher level of brine injection and by optimizing the vacuum cooling conditions.

Available documents

Format PDF

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).