Hydrocarbons as substitutes for halogenated refrigerants in refrigerating systems.

Summary

The paper deals with the use of R290-R600a (50-50) and R600a as alternative to R134 to substitute R12 in domestic refrigeration. A theoretical analysis of the mixture performance shows that both hydrocarbon refrigerants may be used. Tests of certain hermetic compressors confirm that the mixture can be used both for old and new equipment, while the isobutane must be used for new equipment only.

Details

  • Original title: Hydrocarbons as substitutes for halogenated refrigerants in refrigerating systems.
  • Record ID : 1995-0797
  • Languages: English
  • Source: Proceedings of the 1994 International Refrigeration Conference at Purdue.
  • Publication date: 1994/07/19
  • Document available for consultation in the library of the IIR headquarters only.