Investigation of using non-azeotropic refrigerant mixture as the replacement of R12.

Author(s) : MA Y., WEI J., YANG Z., et al.

Summary

Tests on water-to-water heat pump and two-evaporator refrigerator-freezer using R22/R142b as alternative to R12 are presented. The tests show R22/R142b is energy conserving when strict counterflow heat exchangers are used. The refrigerator-freezer system is adjusted to match the thermodynamic characteristics of R22/R142b. Energy consumption has been reduced. The analysis shows using non-azeotropic refrigerant mixtures as short or mid-term alternatives to CFCs would be a good choice.

Details

  • Original title: Investigation of using non-azeotropic refrigerant mixture as the replacement of R12.
  • Record ID : 1993-0124
  • Languages: English
  • Publication date: 1992/07/14
  • Source: Source: Proc. 1992 int. Refrig. Conf., Energy Effic. New Refrig., Purdue Univ.
    vol. 2; 669-676; 5 fig.; 3 tabl.; 5 ref.