Moisture solubility in R123 and R134a.

Summary

The objective of this project was to determine the solubility of water in the two chlorofluorocarbon (CFC) alternatives R123 and R134a at a number of different temperatures in the range of -25 to 60 deg C. The authors used the high-field, high-resolution NMR spectroscopy to measure the solubility of water in R123 and R134a. Their study was modelled after a recent report on the determination of the solubility of water in carbon tetrachloride, chloroform, and dichloromethane by proton NMR spectroscopy. Measurements at a minimum of 13 different temperatures were made on each liquid refrigerant saturated with water but without any oil.

Details

  • Original title: Moisture solubility in R123 and R134a.
  • Record ID : 1994-3391
  • Languages: English
  • Source: ASHRAE Transactions 1994.
  • Publication date: 1994
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles from the proceedings (72)
See the conference proceedings

Indexing