IIR document
Performance of a low-GWP near-azeotropic alternative to R410A.
Author(s) : COLBOURNE D., COX N., SUEN K. O., et al.
Summary
There has been a notable uptake in the use of R410A in small sized air-conditioning systems, largely due to its supposed superior efficiency compared to the other widely used HFCs. Its higher pressure also enables a more compact system design. However, R410A possesses a high GWP, and is therefore viewed negatively from an environmental perspective. The current work presents a performance study on a low-GWP alternative to R410A, which is a near-azeotropic mixture based on R1270 (propylene) and R161. The study comprises a modelling exercise and a series of measurements, in a purpose-built test rig, to compare the performance of the chosen composition of the R161/R170 mixture with R410A.
Available documents
Format PDF
Pages: 2008-2
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Performance of a low-GWP near-azeotropic alternative to R410A.
- Record ID : 2009-0530
- Languages: English
- Source: 8th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2008)
- Publication date: 2008/09/07
Links
See other articles from the proceedings (132)
See the conference proceedings
Indexing
-
Themes:
Hydrocarbons;
Other refrigerants;
Blends - Keywords: R410A; R161; Propylene; Comparison; Substitute; Performance; Modelling; Azeotropic mixture; Expérimentation; Refrigerant
-
New high pressure low-GWP azeotropic and near-a...
- Author(s) : COX N., MAZUR V., COLBOURNE D.
- Date : 2008/07/14
- Languages : English
- Source: 2008 Purdue Conferences. 19th International Compressor Engineering Conference at Purdue & 12th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
- Formats : PDF
View record
-
Phase equilibria in low GWP azeotropic refriger...
- Author(s) : ARTEMENKO S., COX N., COULBORNE D., et al.
- Date : 2009/06/23
- Languages : English
- Source: 3rd Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Formats : PDF
View record
-
Performance d'un fluide quasi-azéotrope à faibl...
- Author(s) : COLBOURNE D., COX N., SUEN K. O., et al.
- Date : 2009/04
- Languages : French
- Source: Rev. gén. Froid - vol. 99 - n. 1092
View record
-
Performance evaluation of near-azeotropic R-502...
- Author(s) : SHIN J. S., KIM M. H.
- Date : 2006/05/29
- Languages : English
- Source: 7th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2006). Proceedings
- Formats : PDF
View record
-
Quasiazeotrope blend of propane/R134a, an alter...
- Author(s) : MALEK A., GOTH Y.
- Date : 2001/04/01
- Languages : English
- Source: Arab-African Conference for Refrigeration and Air Conditioning.
View record