IIR document
Performance of heat pumps charged with R170/R290 mixture.
Author(s) : KANG D. G., PARK K. J., JUNG D.
Summary
In this study, thermodynamic performance of R170/R290 mixture is measured on a heat pump bench tester in an attempt to substitute R22. The bench tester is equipped with a commercial hermetic rotary compressor providing a nominal capacity of 3.5 kW. All tests are conducted under the summer cooling and winter heating conditions of 7/45 and -7/41°C in the evaporator and condenser, respectively. During the tests, the composition of R170 is varied from 0 to 10% with an interval of 2% for R170/R290 mixture. Test results show that the COP and capacity of R290 are up to 15.4% higher and 7.5% lower than those of R22 for two conditions, respectively. For R170/R290 mixture, the COP decreases and the capacity increases with an increase in the amount of R170. The mixture of R170/R290 (4/96) shows a similar capacity and COP as those of R22. For the mixture, the compressor discharge temperature is 17-28°C lower than that of R22. For R170/R290 mixture, there is no problem with mineral oil since the mixture is composed of hydrocarbons. The amount of charge is reduced up to 58% as compared to R22. Overall, R170/R290 mixture is a good long term 'drop-in' candidate to replace R22 in residential air-conditioners and heat pumps.
Available documents
Format PDF
Pages: 2009-5
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Performance of heat pumps charged with R170/R290 mixture.
- Record ID : 2009-2164
- Languages: English
- Source: 3rd Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Publication date: 2009/06/23
Links
- See translations: Prestaciones de bombas de calor cargadas con mezcla R170/R290.
See other articles from the proceedings (66)
See the conference proceedings
Indexing
-
Themes:
Heat pumps techniques;
Hydrocarbons;
Blends - Keywords: Measurement; R170; Propane; Heat pump; Performance; Binary mixture; Ethane; Testing; COP; Refrigerant; Water-water
-
Charge and COP optimization of a reversible wat...
- Author(s) : MARTÍNEZ I. O., GONZÁLVEZ J., CORBERÁN J. M.
- Date : 2006/05/29
- Languages : English
- Source: 7th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2006). Proceedings
- Formats : PDF
View record
-
Development and performance characterisation of...
- Author(s) : CORBERÁN J. M., GONZÁLVEZ J., MARTÍNEZ I. O., et al.
- Date : 2008/09/07
- Languages : English
- Source: 8th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2008)
- Formats : PDF
View record
-
Performance of a 100 kW low charge heat pump us...
- Author(s) : DEL COL D., CAVALLINI A., DA RIVA E., et al.
- Date : 2008/09/07
- Languages : English
- Source: 8th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2008)
- Formats : PDF
View record
-
POMPE A CHALEUR A ABSORPTION AVEC FLUIDE AUXILI...
- Author(s) : ROJEY A., CHERON J., COHEN C.
- Date : 1987/08/24
- Languages : French
- Source: Development in refrigeration, refrigeration for development. Proceedings of the XVIIth international Congress of Refrigeration.
- Formats : PDF
View record
-
Performance of HCFC-22 alternative natural refr...
- Author(s) : JUNG D. S., HAM Y.
- Date : 2005/05/02
- Languages : English
- Source: 8th IEA Heat Pump Conference 2005: global advances in heat pump technology, applications, and markets. Conference proceedings [CD-ROM].
View record