R22 phase-out in existing installations. 4. Examples of applications and environmental analysis of the impact of changing refrigerants (TEWI, simplified ACV).
Remplacement du R22 dans les installations existantes. 4. Exemples d'applications et analyse environnementale de l'impact du changement de fluide frigorigène (TEWI, ACV simplifiée).
Author(s) : BENSAFI A.
Type of article: Article, Review, Case study
Summary
This fourth chapter provides the reader with examples of practical applications in which R22 can be replaced by an HFC suitable for the required task. In some configurations, changes designed to comply with standards by simply replacing refrigerants are impossible. Retrofitting or simply replacing the systems then has to be considered. Finally, as an example for a water chiller unit, it was demonstrated that the choice could only be final after mathematical analysis of the environmental impact of the new operation mode. See also this issue of the Bulletin, references 2010-0714 and 0717.
Details
- Original title: Remplacement du R22 dans les installations existantes. 4. Exemples d'applications et analyse environnementale de l'impact du changement de fluide frigorigène (TEWI, ACV simplifiée).
- Record ID : 2010-0716
- Languages: French
- Subject: Environment, General information
- Source: Revue générale du Froid & du Conditionnement d'air - vol. 100 - n. 1103
- Publication date: 2010/05
Links
- See also: Remplacement du R22 dans les installations existantes. 3. Les remplaçants du R22, les performances des producteurs.
Remplacement du R22 dans les installations existantes. 1. Réglementation et marché du R22.
Remplacement du R22 dans les installations existantes. 5. Méthodologie pour un parc d'installations : analyse des surcoûts et analyse des difficultés de mise en oeuvre et des conséquences pour les intervenants sur l'installation.
Remplacement du R22 dans les installations existantes. 2. Les fluides de remplacement possibles.
Remplacement du R22 dans les installations existantes. 6. Annexes : comparaison théorique des fluides, impacts environnementaux, machines fonctionnant au CO2.
See the source
Indexing
-
An assessment of the potential for CO2 storage ...
- Author(s) : HOLLOWAY S., GARG A., KAPSHE M., et al.
- Date : 2007/12
- Languages : English
- Source: Greenh. Issues - n. 89
View record
-
Opzioni per la riduzione dell'emissione di HFC ...
- Author(s) : CORCORAN W. M., RUSCH G., SPATZ M. W., et al.
- Date : 2000
- Languages : Italian
- Source: Industria & Formazione - vol. 24 - n. 238
View record
-
Refrigeration and global warming.
- Date : 1997/07
- Languages : English
- Source: Inst. Refrig., Guid. Note - n. 6
View record
-
Assessment of the impact of vapour compression ...
- Author(s) : DE ROSSI F., SASSO M.
- Date : 1994/01
- Languages : Italian
- Source: Industria italiana del Freddo - vol. 48 - n. 1
View record
-
Is the TEWI number suitable for evaluating the ...
- Author(s) : KRUSE H.
- Date : 1998/07
- Languages : English
- Source: HVAC&R Research - vol. 4 - n. 3
View record