R22 phase-out in existing installations. 4. Examples of applications and environmental analysis of the impact of changing refrigerants (TEWI, simplified ACV).
Remplacement du R22 dans les installations existantes. 4. Exemples d'applications et analyse environnementale de l'impact du changement de fluide frigorigène (TEWI, ACV simplifiée).
Author(s) : BENSAFI A.
Type of article: Article, Review, Case study
Summary
This fourth chapter provides the reader with examples of practical applications in which R22 can be replaced by an HFC suitable for the required task. In some configurations, changes designed to comply with standards by simply replacing refrigerants are impossible. Retrofitting or simply replacing the systems then has to be considered. Finally, as an example for a water chiller unit, it was demonstrated that the choice could only be final after mathematical analysis of the environmental impact of the new operation mode. See also this issue of the Bulletin, references 2010-0714 and 0717.
Details
- Original title: Remplacement du R22 dans les installations existantes. 4. Exemples d'applications et analyse environnementale de l'impact du changement de fluide frigorigène (TEWI, ACV simplifiée).
- Record ID : 2010-0716
- Languages: French
- Subject: Environment, General information
- Source: Revue générale du Froid & du Conditionnement d'air - vol. 100 - n. 1103
- Publication date: 2010/05
Links
- See also: Remplacement du R22 dans les installations existantes. 3. Les remplaçants du R22, les performances des producteurs.
Remplacement du R22 dans les installations existantes. 1. Réglementation et marché du R22.
Remplacement du R22 dans les installations existantes. 5. Méthodologie pour un parc d'installations : analyse des surcoûts et analyse des difficultés de mise en oeuvre et des conséquences pour les intervenants sur l'installation.
Remplacement du R22 dans les installations existantes. 2. Les fluides de remplacement possibles.
Remplacement du R22 dans les installations existantes. 6. Annexes : comparaison théorique des fluides, impacts environnementaux, machines fonctionnant au CO2.
See the source
Indexing
-
Total equivalent warming impact of R22 alternat...
- Author(s) : GOPALNARAYANAN S., ROLOTTI G. D.
- Date : 1999
- Languages : English
- Source: ASHRAE Transactions. 1999 Winter Meeting, Chicago, Illinois + CD-ROM.
View record
-
R22-Ausstieg: aus internationaler Sicht.
- Author(s) : REINER G.
- Date : 1998/11/18
- Languages : German
- Source: DKV-Tagungsbericht 25. 1998, Würzburg.
View record
-
Effect of local CO2 release of refrigeration an...
- Author(s) : VÁRSZEGI T., CZÓBEL S., SZIRMAI O.
- Date : 2007/08/21
- Languages : English
- Source: ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
View record
-
Remplacement du R22 dans les installations exis...
- Author(s) : BENSAFI A.
- Date : 2010/07
- Languages : French
- Source: Revue générale du Froid & du Conditionnement d'air - vol. 100 - n. 1105
View record
-
Opzioni per la riduzione dell'emissione di HFC ...
- Author(s) : CORCORAN W. M., RUSCH G., SPATZ M. W., et al.
- Date : 2000
- Languages : Italian
- Source: Industria & Formazione - vol. 24 - n. 238
View record